Add installation points and routes
In the Installations stage you prepare electrical, water, drainage, heating, gas and ventilation work. Every installation follows the same order: source, points, routes. Kaldrix computes routes and lengths; you check the result and fix the places marked with a number.
Prepare the project and access
You need a project with drawn rooms, the Installations project part enabled and permission to change the drawing. Points require the Installations module (Pro and Advanced); circuits, risers and underfloor heating also require Indicative installations (Advanced). Existing accounts keep their earlier features; check Subscription → Features.
Choose an installation
Open 2D/3D Studio → Installations and choose the floor. The Overview panel starts with Choose an installation. Each installation shows its number of points or Done. Choose one from the list; its guide then leads you through three steps.

Installation overview: the list of installations with point counts (Polish interface; example data).
Place points
- Choose + Add → installation points, for example Outlets and devices. Each tile has its plan symbol, and the number in its corner says how many such points already exist.
- Choose a tile and move the cursor over the plan. Next to the cursor you see the room and the place: on the wall, in the floor or on the ceiling.
- move closer to a wall means a wall-mounted point is too far from a wall. Move the cursor and click.
This is a hint before you click; saving decides the final place. In 3D the same tiles are in the What do you want to place? window. Choosing a tile starts placing right away and the list folds to the chosen kind. On a phone, height and circuit are under the Height and circuit button, so the scene stays visible.
Place a point exactly
Drag the point on the plan. A point on a wall slides along it in 1 cm steps, and you see its distance from the left and right corner of the room. A dashed line shows that it lines up with another point. Esc cancels the move without saving.
Type an exact dimension in the point card: From the left corner or From the right corner, in centimetres. Left and right are as you see the wall when standing in the room. Arrow keys move the selected point by 1 cm, and Ctrl+D places a copy next to it.
In 3D, Horizontally moves the point along the wall without changing its height, and Up / down changes only the height.
Suggest circuits and check routes
In the third step of the guide, choose Suggest circuits. Review the proposal, use Show routes on the plan if needed, and save.
Above the circuit list, Routes to check shows numbered warnings. On the 2D plan the same number stands next to the problem. Tap the row or the number to open the circuit and fix its points or route. No route problems means the computed routes have no warnings.

A route warning numbered 1 in the panel and on the plan (Polish interface; example data).
A warning does not block saving, but it shows what to check. Kaldrix does not confirm that the installation meets regulations or that protective devices are correctly sized.
Exercise: an oven on a socket circuit
- In electrical, suggest and save circuits for the sample room.
- Place an Oven at a wall and choose the socket circuit in the Circuit field.
- Check Routes to check: a numbered warning appears and the same number stands next to the oven.
- Tap the warning. In the opened circuit, choose Points and disconnect the oven from the circuit.
Result: the section shows No route problems and the socket circuit no longer includes the oven. Then create a separate circuit for the oven.
Next steps
Check installation quantities in measurements and quantities. Prepare the drawing with Draw and check a floor plan.